legal · go-v.org

Collecting oral fluid specimens for alcohol and drug testing.

CFR · 2024-01-01 · US · Title 10

(a) To perform the initial specimen collection, the collector shall— (1) Check the expiration date on the device and show it to the donor (the device may not be used after its expiration date); (2) Open an individually wrapped or sealed package containing the device in the presence of the donor; (3) Offer the donor the choice of using the device or having the collector use it. If the donor chooses to use it, instruct the donor to insert the device into his or her mouth and use it in the manner described by the device's manufacturer; (4) If the donor chooses not to use the device, or in all cases when a new specimen collection is necessary because the device failed to activate, insert the device into the donor's mouth, and gather oral fluids in the manner described by the device's manufacturer (wear single-use examination or similar gloves while doing so and change them following each specimen collection); and (5) When the device is removed from the donor's mouth, follow the manufacturer's instructions regarding necessary next steps to ensure that the device has activated. (b) If the steps in paragraph (a) of this section could not be completed successfully (e.g., the device breaks, the device is dropped on the floor, the device fails to activate), the collector shall— (1) Discard the device and conduct a new specimen collection using a new device. The new device must be one that has been under the collector's control before the specimen collection; (2) Record the reason for t

official document · source cfr-2024 · id 10:§ 26.97