Design and performance criteria for sources.
CFR · 2024-01-01 · US · Title 10
(a) A licensee may use a sealed source for use in well logging applications if— (1) The sealed source is doubly encapsulated; (2) The sealed source contains licensed material whose chemical and physical forms are as insoluble and nondispersible as practical; and (3) Meets the requirements of paragraph (b), (c), or (d) of this section. (b) For a sealed source manufactured on or before July 14, 1989, a licensee may use the sealed source, for use in well logging applications if it meets the requirements of USASI N5.10-1968, “Classification of Sealed Radioactive Sources,” or the requirements in paragraph (c) or (d) of this section. (c) For a sealed source manufactured after July 14, 1989, a licensee may use the sealed source, for use in well logging applications if it meets the oil-well logging requirements of ANSI/HPS N43.6-1997, “Sealed Radioactive Sources—Classification.” (d) For a sealed source manufactured after July 14, 1989, a licensee may use the sealed source, for use in well logging applications, if— (1) The sealed source's prototype has been tested and found to maintain its integrity after each of the following tests: (i) (ii) (iii) (iv) (v) (e) The requirements in paragraphs (a), (b), (c), and (d) of this section do not apply to sealed sources that contain licensed material in gaseous form. (f) The requirements in paragraphs (a), (b), (c), and (d) of this section do not apply to energy compensation sources (ECS). ECSs must be registered with the Commission under § 32.
official document · source cfr-2024 · id 10:§ 39.41