Operating tests.
CFR · 2024-01-01 · US · Title 10
(a) (1) Perform pre-startup procedures for the facility, including operating of those controls associated with plant equipment that could affect reactivity. (2) Manipulate the console controls as required to operate the facility between shutdown and designated power levels. (3) Identify annunciators and condition-indicating signals and perform appropriate remedial actions where appropriate. (4) Identify the instrumentation systems and the significance of facility instrument readings. (5) Observe and safely control the operating behavior characteristics of the facility. (6) Perform control manipulations required to obtain desired operating results during normal, abnormal, and emergency situations. (7) Safely operate the facility's heat removal systems, including primary coolant, emergency coolant, and decay heat removal systems, and identify the relations of the proper operation of these systems to the operation of the facility. (8) Safely operate the facility's auxiliary and emergency systems, including operation of those controls associated with plant equipment that could affect reactivity or the release of radioactive materials to the environment. (9) Demonstrate or describe the use and function of the facility's radiation monitoring systems, including fixed radiation monitors and alarms, portable survey instruments, and personnel monitoring equipment. (10) Demonstrate knowledge of significant radiation hazards, including permissible levels in excess of those authorized, an
official document · source cfr-2024 · id 10:§ 55.45